This page was exported from Free Exams Dumps Materials [ http://exams.dumpsmaterials.com ] Export date:Wed Jan 29 0:33:39 2025 / +0000 GMT ___________________________________________________ Title: [Jul-2024] NACE-CIP2-001 Exam Dumps Pass with Updated 2024 Coating Inspector Level 2 [Q48-Q68] --------------------------------------------------- [Jul-2024] NACE-CIP2-001 Exam Dumps Pass with Updated 2024 Coating Inspector Level 2 Free NACE-CIP2-001 Exam Dumps to Pass Exam Easily The benefits of earning the NACE-CIP2-001 certification are numerous. Coating Inspector Level 2 certification is recognized worldwide as a symbol of excellence in the coating inspection industry. It can help professionals advance their careers, increase their earning potential, and gain credibility and respect within the industry.   NO.48 Surface preparation of concrete is performed using:  Methods that are exactly the same as steel  Methods that are completely different to steel  Methods that have been modified for concrete  Methods that are the same as wood NO.49 You have just your NACE CIP Level 2 certification when you are asked to supervise a team of uncertified field pipeline inspectors.Your FIRST preferred course of action is to:  Accept assignment without hesitation  Advise the prospective employer that you cannot accept the position  Meet with the prospective employer to scope of your role  Review the NACE Attestation prior to making a decision NO.50 You are the NACE Level 2 Coating Inspector where SSPC PA 2 has been specified with an additional requirement that no individual gauge reading shall be below a certain value.As this is not part of the standard you should:  Ignore the additional requirement  Enforce the additional requirement  Call your supervisor  Request clarification from the specifier NO.51 You are working as an inspector in a galvanizing plant for the first time.What are some of the hazards you need to be aware of:  Risk of chemical exposure  Risk of skin  Risk of acid or caustic splashes  a), b), and c) NO.52 Because a NACE Level 2 Inspector has been trained in specific destructive tests, it is up to the Inspector to decide if and when a destructive test is required.  True  False NO.53 Which surface preparation method uses a dilute acid solution to remove laitance and I roughen the concrete surface?  Sacking  Acid etching  Stoning  High-pressure water washing NO.54 Antifouling coatings are regulated by international treaties.  True  False NO.55 The primary purpose of Fireproofing coatings are to provide:  fire extinguishing characteristics  Temporary protection for the structure  Preferential fuel for the fire  Explosion resistance NO.56 Inspection and Test Plans are provided to:  Outline the inspection steps, sequencing and pass/fail criteria  So the Inspector doesn’t have to read the entire specification  To supersede the requirements of the product data sheets  So the contractor has a single document to reference NO.57 Which product, when closely inspected has a green or red layer of fusion bonded epoxy (FBE) that is visible directly on the steel?  2-Layer Polyethylene (PE)  3-Layer Polyethylene (PE)  Fusion Bonded Epoxy  Coal Tar Enamel NO.58 Measuring methyl ethyl ketone (MEK) resistance of ethyl silicate inorganic zinc-rich primers by solvent rub requires  25 single rubs with a saturated cloth.  35 single rubs with a saturated cloth.  50 double rubs with a saturated cloth.  25 double rubs with a saturated cloth. NO.59 When performing inspection in accordance with ASTM D 4138 the Inspector will use:  A set of 14 pencils of varying hardness  A destructive paint inspection Tooke gauge  A mechanical adhesion tester  A hardness tester NO.60 NACE International Standards are developed by:  Government mandates  International mandates  Standard committees  Regional mandates NO.61 Galvanizing performs best in which of the following exposures:  pH below 4  pH above 12  pH between 5-10  pH of 13 NO.62 The number of air turns in an enclosure can be affected by all of these EXCEPT  time of the year (winter/summer).  type of dehumidification equipment (refrigerant or desiccant).  manufacturer of the equipment.  coating type. NO.63 Corrosion is the reverse process of  hot dipping.  steel manufacturing.  flaking.  galvanic deterioration. NO.64 You should bulk store coatings containing isocyanates  in a well ventilated area separate from the work place.  in a heated warehouse.  in a refrigerated warehouses  wherever it is convenient NO.65 Which is used to calibrate a pH meter?  Distilled water  Deionized water  Standard solvent solution  Standard buffer solution NO.66 WJ-1 is always performed using UHWJ at pressures above 210 MPa (30,000 PSI)  True  False NO.67 Cold-applied tape  are identifiable by its distinct colors, usually light blue, green, Or Grey.  is typically green or led and looks like “painted” finish.  have a cross-linked polyethylene backing and a heat-activated adhesive.  is polyethylene film, heat laminated, ‘With an adhesive layer of butyl glue. NO.68 The Inspectors’ goal at the Pre-Job Conference is to:  Obtain a clear understanding of the Specification  Discuss contractual requirements  Manage the meeting so it doesn’t go off topic  Take accurate meeting minutes for distribution  Loading … NACE-CIP2-001 Exam Dumps, NACE-CIP2-001 Practice Test Questions: https://www.dumpsmaterials.com/NACE-CIP2-001-real-torrent.html --------------------------------------------------- Images: https://exams.dumpsmaterials.com/wp-content/plugins/watu/loading.gif https://exams.dumpsmaterials.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2024-07-01 13:50:21 Post date GMT: 2024-07-01 13:50:21 Post modified date: 2024-07-01 13:50:21 Post modified date GMT: 2024-07-01 13:50:21