QUESTION 58
A PV system designer is selecting an inverter for a 12 kW array with a maximum power point voltage range of 300-450V DC. Which inverter specification is most critical to verify compatibility?

 
 
 
 

QUESTION 59
A residential PV system uses two 120.240Vac utility-interactive inverters with a sealed lead-acid battery energy backup for protected loads. The MOST important protected load consideration when operating in the backup mode is that:

 
 
 
 

QUESTION 60
A 5 kW system has a daily output of 20 kWh at 5 PSH. What is the total derate factor?

 
 
 
 

QUESTION 61
A commercial 600v carport-mounted PV system is installed with rigid running under the parking lot to an inverter pad located at the edge of the parking lot. At what depth below the parkinglot base MUST condult be buried?

 
 
 
 

QUESTION 62
During a PV system inspection, an installer notices that the rapid shutdown system fails to de-energize the array within 30 seconds of initiation. What is the most likely cause based on NEC 690.12 requirements?

 
 
 
 

QUESTION 63
A 15 kW system has a total derate factor of 0.90. After 5 years, output drops by 2% annually due to degradation. What is the AC output in year 5?

 
 
 
 

QUESTION 64
An installer is sizing conductors for a 200-foot PV source circuit with a current of 8A at 400V DC. The design specifies a 1.5% voltage drop using copper wire at 30°C. What is the minimum wire size required?

 
 
 
 

QUESTION 65
A module’s STC power is 300W, with a temperature coefficient of -0.40%/°C. At 65°C, what is the power loss percentage?

 
 
 
 

QUESTION 66
A PV system’s capacity factor is 18%. The array is 10 kW, and it operates 365 days/year. What is the annual energy output?

 
 
 
 

QUESTION 67
A PV system was installed in July 2017 under the 2017 NEC. The system has a string inverter located inside a garage on a wall 10 ft, from the outside wall and 1oft, from the ac load center at the point of utility connection. The PV system has a PV array on the roof. Which of the following represents the PV rapid shutdown system requirement for the controlled PV system conductors associated with this PV array?

 
 
 
 

QUESTION 68
According to the NEC, if the PV system disconnect and the building service disconnect are at different locations, there MUST be a/an:

 
 
 
 

QUESTION 69
A worker is installing modules on a roof 20 feet above grade. What OSHA fall protection is required?

 
 
 
 

QUESTION 70
A 10 kW system has a total derate factor of 0.85 and operates at 5 PSH. What is the daily output in summer with 10% soiling loss?

 
 
 
 

QUESTION 71
An installer was asked to provide a means to measure the voltage of each battery in a system. The bank is located 50 ft.
From the data logger. The installer will be using shielded. Twisted pairs of instrumentation wiring, all run in the bundle a conduct.
The signals are connected to isolated and ungrounded inputs at a data logger. Which safely precaution is MOST needed to protect the instrumentation wiring?

 
 
 
 

QUESTION 72
A grid-connected PV system on a dwelling is producing 30% less power than expected. The conductors from threes strings of modules enter into a 3-pole fused dc disconnect, and each ungrounded conductor is connected to a separate pole. On the inverter side of the switch terminals, the three strings are combined. The dc disconnect switch is opened. The voltages on the array side of theswitchare 440 on string #1, 444V on string
#2, and 0V on string #3. The dc disconnect is then closed and the inverter resumes operating, still producing about 30% less power than expected. A clamp-on ammeter is used to measure the dc current of each string of each string of modules where they enter the rooftop junction box. The operating currents of each string are
3.9A for string #1, 3 85A for string #2, and 4.3 A for string #3. What is the MOST likely with the system?

 
 
 
 

QUESTION 73
During a site assessment, an installer identifies a 100-foot-tall tree 150 feet south of a proposed PVarray. The site latitude is 40°N. Will this tree cause shading on December 21st between 9 AM and 3 PM solar time?

 
 
 
 

QUESTION 74
The following dc portion of a PV schematic (functionally grounded conductor not shown) is submitted to the building official for permit approval. The building official, who also is he AHJ, allow the system to be installed by requiring what NEC-required MINIMUM size equipment grounding conductor at Location A?

 
 
 
 

QUESTION 75
With all other environmental parameters being the same, which would be the expected reduction in KM performance of a PV system after an irradiance drop from 810w/m2 to 740w/m2?

 
 
 
 

QUESTION 76
A system’s annual output decreases by 10% due to shading. The original output was 20,000 kWh. What is the new output?

 
 
 
 

The PVIP certification is highly valued in the industry and is recognized as a mark of excellence in the field of solar energy. It is one of the few certifications that require candidates to have hands-on experience in PV system installation. Candidates must meet certain eligibility requirements, including a minimum of 58 hours of advanced training in PV installation and at least three years of practical experience in the field.

The North American Board of Certified Energy Practitioners (NABCEP) offers the PV Installation Professional (PVIP) Board Certification for individuals who want to demonstrate their expertise in the solar industry. PV Installation Professional (PVIP) Board Certification certification is designed for professionals who are responsible for the installation of solar photovoltaic (PV) systems, including residential, commercial, and utility-scale applications. The PVIP certification exam covers a wide range of topics, including system design, installation, commissioning, and maintenance, as well as safety and code compliance.

 

100% Free NABCEP Board PVIP Dumps PDF Demo Cert Guide Cover: https://www.dumpsmaterials.com/PVIP-real-torrent.html

         

Related Links: www.stes.tyc.edu.tw www.stes.tyc.edu.tw www.stes.tyc.edu.tw www.stes.tyc.edu.tw www.stes.tyc.edu.tw www.stes.tyc.edu.tw

Leave a Reply

Your email address will not be published. Required fields are marked *

Enter the text from the image below